2024-12-10 |
RUB PM |
Firmware |
2.24.49 |
Bugfix |
Fixed broken signature of status monitor
- Bug was introduced in version 2.24.48.
|
|
2024-11-27 |
RUB PM |
Firmware |
2.24.48 |
New |
DNS servers can be configured
- After configuring DNS servers on "System" page, the Syslog server
as well as NTP client’s hosts can be configured as DNS names rather than IP addresses.
|
|
2024-11-14 |
RUB PM |
Firmware |
2.24.47 |
New |
Added automatic insertion color of MTD timers
- "Read / MTD / Color" in configuration enables insertion of MTD timers with
actual color including automatic color change.
|
Rubidium Configuration Tool |
Software |
2.24.47 |
|
2024-11-12 |
Rubidium Configuration Tool |
Software |
2.24.46 |
New |
Added support for option 87 |
|
2024-09-04 |
Rubidium Configuration Tool |
Software |
2.24.36 |
New |
Added blue display color to MTD timers |
RUB PM-M |
Firmware |
2.24.36 |
|
2024-09-03 |
RUB PM-R |
Firmware |
2.24.36 |
New |
Added blue display color to the Timer Request Protocol |
RUB PM-R |
Manual |
3.2 |
|
2024-08-30 |
RUB PM |
Firmware |
2.24.35 |
Enhanced |
Status monitor certificate update
- The new certificate is valid until October 2027.
|
|
2024-08-29 |
Rubidium Configuration Tool |
Software |
2.24.35 |
New |
Added firmware update check
- Added "Check for Update" button to "System" page for easy downloading of firmware updates.
-
Requires Internet access.
|
|
2024-07-08 |
RUB PM |
Firmware |
2.24.28 |
New |
Added features to PTP Grandmasters
- "Min. Delay Request Interval" can be set.
-
Added an "Antenna Enable" setting for GPI3 output. This allows use of a G16 GPS receiver as a reference of a PTP grandmaster.
|
Rubidium Configuration Tool |
Software |
2.24.28 |
|
2024-06-26 |
RUB PM |
Firmware |
2.24.27 |
New |
Added firmware update check
- Added "Check for Update" button to "Version" or "System" pages for easy downloading of firmware updates.
-
Requires Internet access.
|
|
2024-06-24 |
RUB PM-R |
Firmware |
2.24.25 |
Bugfix |
Fixed "Error 304"
- Possibly occurring when trying to control GT’s MTD timers with
"Controlling" commands of Timer Request Protocol.
|
|
2024-06-14 |
RUB PM |
Firmware |
2.24.23 |
Enhanced |
Several enhancements
- Improved readability of page menu by shadowing item’s background.
-
Showing reference status on MTD page.
-
Showing status monitor’s IP on "System" page.
|
|
2024-04-04 |
RUB PM |
Firmware |
2.24.14 |
New |
Added MTDoE + NTP Client + Timer Request Protocol (M+C+R) firmware image |
Rubidium Configuration Tool |
Software |
2.24.14 |
|
2024-04-04 |
RUB PM-M |
Firmware |
2.24.14 |
Bugfix |
Fixed default value of MTD Priority |
|
2024-03-01 |
RUB PM |
Firmware |
2.24.11 |
New |
Added support for option 86 |
Rubidium Configuration Tool |
Software |
2.24.11 |
|
2024-01-31 |
RUB PM-S |
Firmware |
2.24.5 |
Enhanced |
Added more PTP status OIDs to SNMP MIB
- SNMP status OIDs that are calculated from bit fields were fixed.
- .
SNMP requests of EUI64 OIDs are now possible.
|
Rubidium Configuration Tool |
Software |
2.24.5 |
|
2024-01-26 |
RUB PM |
Firmware |
2.24.4 |
Bugfix |
Fixed message "File \WEB\OptAut42.htm not found"
- Applies to GT with option A (Automation).
-
Bug was introduced with version 2.22.8.
|
|
2024-01-08 |
RUB PM-N |
Firmware |
2.24.1 |
Enhanced |
Allow reference telegrams from 2036-01-01 or later
- On 2036-02-07 NTP timestamps will rollover to zero,
NTP era 0 ends and era 1 starts. The NTP server is now able to work beyond this date.
-
NTP clients are responsible to handle the rollover correctly and not jump back to 1900-01-01.
|
|
2024-01-01 |
RUB PM-N |
Firmware |
2.20.37 |
Bugfix |
The NTP Server stopped working on 2024-01-01
- The NTP server of firmware older than version 2.20.37 ignored reference
telegrams after 2024-01-01. The result was a LOST or INIT state of the NTP server.
-
MTD over Ethernet (MTDoE) was also affected.
|
|